Language:
Katalog nur für gewerbliche Kunden. Alle Preise zzgl. MwSt.[Preise inklusive MwSt zeigen]
Shipping country set to Germany

AE AG6 ANNUNCIATOR GAUGE METER

Avionics_Annunciators_AE-AG6-ANNUNCIATOR--GAUGE-METER

AE AG6 ANNUNCIATOR  GAUGE METER


One Button,Multi-function,Aircraft Annunciator
Fuel Gauge, Several styles available (with low fuel warning and caution zones)

Volt Meter & Current Meter (with low & high warnings and caution zones)

The AG6 is a full service Aircraft Annunciator, Fuel Gauge, Oil Level Gauge, Volt Meter & Current Meter. The annunciator will display many different aircraft warnings. All devices feature user programmable alarms. The AG6 utilizes a push-button LCD display that is backlight with a 3 color LED. All functions are fully programmable by the user. The push-button/display can be used for programming, acknowledging the alarms, and paging thru up to 16 different screens or "annunciator points". The AG6 can automatically scan thru each screen or it can be done manually using the push-button. The pilot has the ability to mask or unmask annoyance alarms.

NOTE: Input devices not included. It is up to the user to provide input devices such as fuel senders, shunts, oil level sensors and input switches to drive the AG6

INSTALLATION MADE EASY

DISPLAY & PUSH BUTTON
Display can be easily mounted in the panel anywhere you can make a square hole. It is a snap to install ! Measures 1.25" wide by 1.0625" high by 1.375" deep, including bezel housing

SIGNAL INPUT BOARD
Signal input/driver board mounts lower in the instrument panel for easier wiring. This permits a better location of inputs & connections in a crowded aircraft. Measures 2.25" wide by 2.5" high.

RIBBON CABLE
The 18" ribbon cable makes it easy to install and remove if necessary. Plugs are provided at both ends.

   
FEATURES

INPUTS
The AG6 will accept up to 6 input signals. (If the audio output is used, only 5 inputs are available.) All inputs will accept signal ranges from (0 to 0.200V) to (0 to 16.383V). Inputs can come from simple on/off switches, aircraft shunts, resistive sensors such as fuel senders, or analog signals from other equipment. All inputs can be configured for a filter or delay. These filter time constants are fully programmable. Filtering may be used to eliminate noisy signals and/or lengthen signal response times.NOTE: Input devices are NOT included. It is up to the user to provide input devices such as fuel senders, shunts, and switches to drive the AG6.

SHUNT INPUT
There is one special input for a shunt. It can be used to monitor aircraft current. This shunt can be placed in aircraft's plus or minus leg of the power circuit. No isolation is necessary. This input will accept signals from (0to 0.050V) to (0 to 0.250V). This is the range of most aircraft shunts. NOTE: If this input is utilized, input terminal #5 cannot be used. The shunt signal will become input signal #5.

ALARMS
When there is a valid alarm, the display screen will blink. If the audio output option is selected, it also will sound. The pilot can temporarily mask or switch off any annoyance alarms using the push button. When the alarm is masked, the display depicts a little triangle in the upper right hand corner of the screen. It can also be easily turned back on. The annunciator features two, three, four, or five zone alarms for maximum flexibility. All alarm set points and alarm delays are fully programmable.

SOUND OUTPUT
An audio output is also provided when there is a valid alarm. This output can be wired into the aircraft's sound system. An on board amplitude adjustment is provided. NOTE: If the sound output option is utilized, only 5 inputs will be available. Input terminal #6 will be used for the sound output.

GAUGE CHARACTERISTICS
Operation of the fuel gauge is depicted below. When the fuel reaches a low level caution point, the display is yellow. When the fuel reaches the low fuel point, the display blinks red. The pilot can acknowledge the alarm by pressing the button. The alarm will stop flashing but will remain red. The audio output will also stop.

INPUT POWER
Input power is 12Vdc only. Current draw is less than 0.060A (60mA) with the LED back light on.

OPERATION
There are two different operating modes, manual and automatic. In the automatic mode, the AG6 automatically scans thru each point or screen and then starts over again. The manual mode operates in a similar fashion except that the user can use the push button to toggle thru the different screens stopping at any screen. You can easily switch from mode to mode using the push button.

Click here to see all screens available PDF


= Available today
= Available in 3-10 days
= Available in 12 days
= Unknown (3 weeks or more)
AE AG6-12V ANNUNCIATOR GAUGE METER10-04180AE AG6-12V ANNUNCIATOR GAUGE METER238.91 EURplease call
Log in
Email:
Password:

Shopping cart is empty
Visit Our Facebook Fan Page
Visit Our Instagram Account
Call us at +49 7634 9057700 from 08:00 to 13:00 CET
Email: info@aircraftspruce.eu Phone: +49 76349057700 (monday-friday 08:00-13:00 CET)